Two Hand Button Control Module

Brand: ESPE

Model: ESRH-3A1B Series

Product Feature:

1. Design according to ISO13849-1 (Category 4 Ple);

2. Relay output: 3NO and 1 NC auxiliary contacts;

3. Inside circuit with cross-diagnose monitoring function;

4. Visualized status indicator for easy diagnoses;

5. Input power overvoltage protection.

 

Product Details

Parameter of two hand button control module

Standard level
Reference standard ISO 13849-1
Safety level ISO 13849-1 Category 4/Ple
Electric parameter
Power supply  DC24V±10%
Consumption <3W
Response time <20ms
Suction buffer time <100ms
Power-on restart time <1s
Protective circuit Overvoltage protection, reverse polarity protection
Safety input Two hand button signal
Input synchronization ≤500ms(Typical data200ms)
Safety output 3NO contacts, and 1 NC auxiliary contacts
B10 data Rated load: 400,000 times, low load: 2,000,000 times
Contact capacity AC15:5A/250V;DC13:6A/24V
Electric lifetime ≥100,000 times (1NO:5A 250VAC,Resistive load)
Mechanical lifetime ≥10,000,000 times
Environment
Vibration resistance Frequency 10Hz-55Hz, amplitude 0.35±0.05mm, 20 times each in X,Y and Z direction
Impact resistance Acceleration 10g, pulse duration 16ms, 1000 times each in X, Yand Z direction
Working temperature -10℃~+55℃
Storage temperature -40℃~+85℃
Protection level Enclosure: IP40 Terminal: IP20
Installation/ Structure
Installation 35mm DIN navigation
Wire size 0.2~2.5mm²
Size 117 x 100.6 x 22.5

 

Product Size

 

Wiring diagram

 

 

Model selection (e.g: ESR□ -3A1B-E)

 

Panel function

 

Application details

Two hand button control module ESRH-3A1B supply 3 safety contacts output and 1 auxiliary contacts output in loop. Connectthe A1 terminal to positive of DC24V power supply, A2 terminal to the negative of power supply, when the signal of input loopS11 S21 is correct and reset loop active, the two hand button control module works.

 

Functional diagram

 

Automatic reset Input loop

● ESRH-3A1B: connect Y1-Y2.

● When input loop S11 and S21 input active signal, component start to work.

● When input loop input active signal to two hand button, reset loop active, the K1 K2 of relay keep disconnecting, indicator light CH1 CH2 light on, safety contacts 13-14/23-24/33-34 close, auxiliary 41-42 disconnected.

● Dual-channel input, connect S11 & S21 of relay to two handbutton respectively, at the mean time connect NO/NC of twohand button as diagram.

● Input loop disconnect (Input loop without active signal to ESRH-3A1B), reset loop active, the K1 &K2 of relay get disconnected,indicator CH1, CH2 light off, safety contacts 13-14/23-24/33-34get disconnected, auxiliary 41-42 close.

Product Installation
Please cut off the power supply when mounting, and ensure no dangerous voltage of machine, except the lightingdevice and spare sockets; Clip the product directly onto 35mm rail inside the equipment cabinet. Before poweringon, please check to ensure cable connection is correct and the product is fastened to the mounting rail.Before disassembling the product, you must cut off the power supply to the machine, then loosen the locking screwsor remove terminals.
Installation diagram Removal diagram

 

Carefully read the manual before installation, and ensure power supply is cut off when wiring.Wiring with power is prohibited.