Brand: ESPE
Model: SLM21 series
Product Feature:
1. Multiple contacts for selection;
2. Holding force 1300N;
3. Ip67 protection rate;
4. Various inserting direction;
5. Support general load or micro-load.
Brand: ESPE
Model: SLM21 series
Product Feature:
1. Multiple contacts for selection;
2. Holding force 1300N;
3. Ip67 protection rate;
4. Various inserting direction;
5. Support general load or micro-load.
Product Details
Parameter of safety door switch
Electromagnetic tube | ||
Rated Voltage | DC24V | |
Capacity | 4.8W | |
Rated current | Approximate 200mA | |
Insulation | Clas N (130°C) | |
LED indicator | ||
Rated voltage | DC24V | |
Rated current | Approximate 1mA | |
Luminous color (LED) | Green | |
Safety level | ||
Certificate | CE TUV | |
Standard | EN60947-5-1, GB14048.5, IEC61508, EN ISO 14119 | |
Protection rate | IP67 | |
Material | PA66 fire retardant | |
Mechanical lifespan | >1 million | |
Electrical lifespan | Over 150, 000 times (AC240V3A, resistive load) | |
Using Type | AC-15 | DC-13 |
Rated operating voltage(Ue) | 240V | 24V |
Rated operating current(Ie) | 3A | 2A |
Electrical parameter | ||
Contact resistance | <24mΩ | |
Nominal discharge current (lth) | 10A | |
Rated insulation voltage (Ui) | 300V | |
Anti-electric shock level | Class II (double insulation) | |
Pulse withstand voltage (EN60947-5-1) | 2.5kv | |
Insulation resistance | >100mΩ | |
Short-circuit protection | 10A, 250V requires a quick-break fuse | |
Vibration resistance | 10-55HZ, double amplitude 1.5mm | |
Compact resistance | Durability 1000/S², mal-operation 300m/S² | |
Conditional short-circuit current | 100A (EN60947-5-1) | |
Space of contact | Above 2 x 2mm | |
Action characteristic | ||
Direct opening force | Minimum 60N | |
Direct opening travel | Over 10mm | |
Allowed operating speed | 0.1m-0.5m/s | |
Allowed operating frequency | Maximum 30 times/minute | |
Holding force | 1300N | |
Environment | ||
Operating environment | 3 (EN60947-5-1) | |
Operating temperature | -10°C to 55°C ( no freezing) | |
Operating humidity | <95% RH |
Product Size
Explanation Model (example:SLM21-BPMF2)
Structure And Action
Below wire diagram for switch with key inserts & lock status. (Terminal 12 &41, 22&51, 32&61 is inside connection)
Product installation
Releasing the 4 screws on top of the cap, spinning the direction of top cap until the suitable position for key inserting | ![]() |
When install on side hung door, it should be over than semidiameter. | ![]() |
Please install the safety switch door and insertion key under range 1-3.5mm. | ![]() |
The installation of operation key allows ±1mm error within the key insertion center of the hole. | ![]() |