No-dead zone safety light curtain

Brand: ESPE

Model: EFP Series

Product Feature:

1. Inquire to get latest price, goods can be finished within 2-3 working days.

2. EFP series is no dead-zone safety light curtain, in accordance with EU type 4 safety standards. 

3. Adopting the internal MCU redundancy design, the safety light curtain has periodic self-inspection & mutual check function. Redundantdual output loop to ensure high security.

 

Product Details

Parameter of safety light curtain

Reference standard

EN 61496-1 (Type 4 ESPE)

EN 61496-2 (Type 4 AOPD)

EN ISO 13849-1 (Category 4、PLe)

Safety level Type 4
Supply voltage DC24V±20%
Capacity <5W
Beam space 10mm, 20mm
Resolution 15mm, 25mm
Beams 10mm beam space:16, 20……160
20mm beam space: 8, 10……80
Protective height Protective height =(N-1)*beam gap,N is beam quantity.
Wave length 940nm
Response time Response time =(N*0.1ms)+0.4ms, N is beam quantity.
Type of output (OSSD) PNP/NPN semiconductors,current <200mA max, residual voltage: 1 V max. leakage current: 1mA max. (Expect voltage influenced by lengthen wire).
Protective circuit Overload voltage protection, power supply reverse polarity protection, over current protection.
Sensing distance 0.1~2m、0.1~5m (remark: If have light reflection, please let us know)
Anti-optical interference 10000Lux
Sensing method Through-beam type
Synchronization Wire synchronization
Enclosure material Aluminum alloy
Enclosure rating IP65
Housing cross-section 30*28mm
Vibration resistance 10 Hz~55 Hz, amplitude 0.35±0.05mm, 20 times each in X, Y, Z direction
Ambient operating temperature -10℃~55℃(no freezing)
Storage temperature -30℃~70℃(no freezing)
Ambient operating humidity When temperature is 20℃,humidity max 85%

 

Wire Connection

 

Light curtain Cable color Cable mark Function Wiring Explanation
Emitter


Brown 24V Positive pole Connect DC power 24V positive pole
Blue 0V Negative pole Connect DC power 0V negative pole
Grey CP Sync cord Connect receiver CP
Yellow green PE Shielded line Ground/Connect GND
Receiver



Brown 24V Positive pole Connect DC power 24V positive pole
Blue 0V Negative pole Connect DC power 0V negative pole
Grey CP Sync cord Connect receiver CP
Yellow green PE Shielded line Ground/Connect GND
Black OSSD1 Output signal 1 Connect safety input interface 1
White OSSD2 Output signal 2 Connect safety input interface 2
Yellow EDM External device monitoring Connect external normally closed monitoring contact
Green RESET Reset Connect reset button

 

Explanation of Model Number

 

 

Product Size

D: Beam space

H: Protective height

L: Total heightL=upper & bottom cover+upper & bottom dead zone+protective height

H=(Beams-1)* beam space

 

Option for Brackets

Installation picture Bracket Name Brackets Size

L brackets (4 pcs)

M5 sliding blocks (4pcs)

M6 grommet (4 pcs)

M6 pad (4 pcs)

M6*16 screw (4 pcs)